The YHC-6000W continuous wave laser cleaning system is designed for industrial operations that demand maximum throughput. By delivering 6000 watts of continuous laser energy, it achieves cleaning speeds that are simply impossible with lower-power systems – typically 2-3 times faster than 2000W or 3000W systems.

YIHAI LASER recommends evaluating the system against representative workpieces and clearly defined cleaning requirements.

Product Type: Continuous-Wave Fiber Laser Cleaning System
Rated Laser Output: 6000W
Model: YHC-6000W, subject to configuration confirmation

Request a Quote | Discuss Your Cleaning Project

Description

High-Power Laser Cleaning for Large Metal Components and Surface Preparation

The YIHAI 6000W Industrial Continuous Laser Cleaning Machine is designed for businesses evaluating high-power laser technology for industrial surface treatment. It is intended for applications involving rust removal, selected coating removal, oxide removal, and the preparation of compatible metal surfaces for subsequent manufacturing or maintenance processes.

YIHAI 6000W Industrial Continuous Laser Cleaning Machine

For companies working with structural steel, heavy machinery, fabricated metal components, and industrial equipment, surface cleaning can be a significant part of the production workflow. The choice of cleaning technology affects not only processing time, but also surface condition, waste handling, operator safety, and preparation for the next manufacturing step.

This 6000W continuous-wave fiber laser cleaning system provides a high-power option for evaluating those requirements. Its suitability should be determined by the actual contaminant, substrate, required cleaning result, and working environment.

The Productivity Advantage:

A 6000W system allows you to:

  • Clean larger areas in the same timeframe – Where a 3000W system takes 8 hours to clean 240 m² of moderate rust, the  YHC-6000 completes the same job in 3.5 hours.

  • Reduce labor costs – One operator with a 6000W system can often replace 2-3 operators with traditional equipment.

  • Minimize project timelines – Faster cleaning means faster coating, faster inspection, and faster return-to-service.

Built for Continuous Operation:

The YHC-6000 is engineered for 100% duty cycle – it can run continuously for entire shifts without thermal derating. The robust cooling system, industrial-grade components, and sealed laser source ensure reliable operation in demanding environments.

Ideal Applications: Ship hulls, storage tanks, bridges, pipelines, heavy steel structures, offshore platforms, wind turbine towers, and any large-scale industrial surface requiring preparation for coating, welding, or inspection.

System Configuration: What Buyers Should Confirm

The following components are relevant when specifying a high-power continuous laser cleaning system. The final configuration should be confirmed in the quotation rather than inferred from generic product descriptions.

Fiber Laser Source

Fiber Laser Source

The CL-6000-HC uses a 6000W continuous-wave fiber laser from Raycus, with an optional upgrade to JPT/MAX or IPG (premium). Key specifications:

  • Output power: 6000W nominal, adjustable from 10% to 100%.

  • Wavelength: 1064-1080nm, optimized for metal surface absorption.

  • Beam quality: M² < 1.3, enabling tight focusing and high energy density.

  • Stability: ±1.5% fluctuation over 8 hours of continuous operation.

  • Protection: Sealed enclosure (IP65) with active temperature monitoring and fault diagnostics.

2. Handheld Scanning Head – The Operator Interface

6000W Laser cleaning head

The scanning head is the operator’s primary tool. It houses:

  • Galvanometer scanners – High-speed mirrors that direct the beam across the cleaning pattern. Response time < 1ms.

  • Focusing optics – Quick-change lenses (200mm, 300mm, 500mm) for different working distances.

  • Assist gas nozzle – Integrated compressed air or nitrogen delivery.

  • Safety interlocks – Two-stage trigger and tilt sensor prevent accidental firing.

Ergonomic design: Weighing just 3.5kg, the head is balanced for one-handed or two-handed operation. The grip is shaped to reduce fatigue during extended use.

3. Dual-Circuit Water Chiller

Water Chiller

The YHC-6000 chiller provides precision cooling for both the laser source and the scanning head:

  • Cooling capacity: 12kW, sufficient for 6000W operation in ambient temperatures up to 40°C.

  • Dual circuits: Separate cooling loops for the laser source and optics.

  • Stability: ±1°C temperature control.

  • Safety: Flow sensors and temperature alarms automatically shut down the laser if cooling fails.

4. Fume Extraction System

6000W Continuous Laser Rust Removal

Laser ablation produces fine particulate matter. The integrated extraction system captures these particles:

  • Three-stage filtration: Cyclone pre-separator → HEPA (99.99% for ≥0.3μm) → Activated carbon (VOCs).

  • Extraction hood: Adjustable hood mounted near the cleaning area.

  • Auto-cleaning: Pulse-jet system extends filter life.

  • Compliance: Filtered exhaust meets EPA and EU emissions standards.

5. Mobile Cart and Cable Management

The entire system is mounted on a mobile cart for ease of transport:

  • Construction: Powder-coated steel frame with heavy-duty locking casters.

  • Cable management: Integrated cable reel and strain relief to prevent damage.

  • Storage: Dedicated compartments for spare lenses, nozzles, and tooling.

Industrial Applications

Structural Steel Fabrication

Laser Cleaning High-Carbon Steel
laser-cleaning-ship

Structural steel components may require removal of surface rust, mill scale, or other contamination before subsequent processing.

A laser cleaning trial can determine whether the process achieves the required surface condition without unacceptable changes to the substrate.

Where coating preparation is involved, confirm the required surface condition with the coating specification. Do not assume laser cleaning is equivalent to abrasive blasting or meets a specific preparation standard without supporting evidence.

Heavy Equipment Maintenance

Heavy machinery and industrial equipment may accumulate rust, old coatings, grease, and other contamination during service.

The suitable cleaning method depends on the component material, contaminant, accessibility, and sensitivity of nearby parts.

Precision-machined surfaces, seals, electrical components, and heat-sensitive areas may require masking or a different cleaning approach.

Marine and Shipyard Maintenance

Marine structures can contain multiple coating layers and corrosion products accumulated over long periods of service.

Before selecting a laser cleaning process, assess the coating composition, corrosion condition, work area, ventilation, and handling of removed material.

Marine coatings may contain substances that require special safety controls. The absence of abrasive media does not eliminate the need to manage airborne contaminants and waste.

Pipelines and Industrial Vessels

laser removal of surface rust

Pipelines, fittings, and vessels may require cleaning around welds, flanges, or coated surfaces before inspection or repair.

Site access, cable management, hazardous atmospheres, and the properties of the existing coating must be considered when evaluating the equipment.

Tank interiors and confined spaces require particular attention to atmospheric hazards, entry procedures, ventilation, and laser safety.

Safety and Environmental Requirements

A 6000W laser cleaning system is high-power laser equipment and must be installed and operated with appropriate engineering and administrative controls.

Before operation, assess the installation and implement measures suitable for the actual system and workpiece.

Important considerations include:

  • Establishing a controlled laser area and preventing unauthorized access.
  • Selecting laser protective eyewear for the laser wavelength and required optical density.
  • Controlling direct and reflected laser radiation.
  • Using suitable fume extraction for the materials being removed.
  • Assessing potentially hazardous coatings and decomposition products.
  • Handling collected dust, filters, and removed materials appropriately.
  • Providing correct electrical installation and grounding.
  • Maintaining the cooling system according to the manufacturer’s instructions.
  • Training operators in normal operation, emergency procedures, and maintenance.

Outdoor operation should only be considered when the complete system, site conditions, weather exposure, and laser hazard controls have been assessed.

The appropriate safety measures depend on the laser configuration and applicable local regulations. Do not treat a component’s protection rating as proof that the complete system can be operated safely in every environment.

Configuration, Warranty, and International Delivery

Confirm the Configuration Before Ordering

The commercial quotation should identify the laser source, scanning head, cooling system, control system, cables, extraction unit, and accessories included in the price.

If alternative laser source brands or optional components are available, the quotation should list each configuration separately.

Warranty and Technical Support

The written warranty should state the coverage period for the laser source, cooling system, scanning head, control system, and other major components.

Before ordering, clarify the service process, available operating documentation, spare-parts availability, remote troubleshooting, and any training or commissioning included in the purchase.

Packaging and Shipping

Packaging and Shipping

For international orders, confirm the packed dimensions, gross weight, packaging method, transport arrangements, insurance, customs responsibilities, and agreed delivery terms.

The electrical supply and installation requirements should be reviewed before dispatch to help prepare the destination site.

YIHAI LASER can discuss the configuration and shipping arrangements according to the buyer’s requirements and destination.

Request a Quote for the YIHAI 6000W Laser Cleaning System

Planning to clean large steel components, industrial equipment, or surfaces requiring coating removal and preparation?

Share your application details with YIHAI LASER so the machine configuration can be reviewed against your actual cleaning requirements.

Contact YIHAI LASER to Discuss Your Application and Request a Quote.

Additional information

Weight 350 kg
Dimensions 100 × 120 × 150 cm
Model

CL-6000W

Laser Type

Continuous-wave fiber laser

Laser Power

6000W (nominal, adjustable 10-100%)

Wavelength

1064-1080nm

Beam Quality (M²)

< 1.3

Power Stability

±1.5% over 8 hours

Scanning Head Type

Handheld galvanometer with ergonomic grip

Maximum Scanning Width

300mm

Scanning Speed

Up to 500 Hz (galvanometer)

Cleaning Width (adjustable)

50mm – 300mm

Working Distance (focus)

200mm (standard) / 300mm / 500mm (optional)

Focus Spot Size

50μm – 500μm (adjustable)

Depth of Focus

±2mm

Optical Fiber Length

15m (standard), 20m (optional)

Control Interface

15″ industrial touch screen, Windows-based

Operating Modes

Pre-set (rust, paint, oil, oxide, multi-layer) + Manual

Parameter Memory

100 user-configurable job profiles

Cooling System

Dual-circuit water chiller, 12kW cooling capacity

Chiller Temperature Control

±1°C

Fume Extraction

Integrated HEPA + activated carbon filtration

Filtration Efficiency

99.99% (≥0.3μm)

Input Power

380V / 50Hz / 3-phase / 45kVA

Laser Source Dimensions

620 × 580 × 450 mm

Scanning Head Weight

3.5 kg

Mobile Cart Dimensions

1,200 × 800 × 1,400 mm

Total System Weight

650 kg

Protection Class

Laser source: IP65 / System: IP54

Certifications

CE, Class 4 laser safety

Laser Source Warranty

2 years